LBC-4000 L-Band Up/Down Converter System with Ethernet

Revision 2

Ethernet-based Remote Product Management

MN-LBC4000A

6–23

6.4.5.3.5

Config | Serial

Use this page to configure LBC‐4000 operating parameters over the EIA‐485/232 serial interface. 
 
 
 
 
 
 
 
 
 
 
 

Figure 6-10. Config | Serial page

Serial

Use the drop‐down menu to select the operating serial mode as RS‐485 or RS‐232.  

Remote Address

Enter a valid remote control address from 0001 to 9999

Baud Rate

Use the drop‐down menu to select the operating baud rate as 10024004800960019200 or 
38400 baud. 

Data bits – Parity – Stop Bits

Use the drop‐down menu to select the asynchronous character format as 8‐N‐1 (8 data bits, no 
parity, 1 stop bit); 7‐O‐2 (7 data bits, odd parity, 2 stop bits); or 7‐E‐2 (7 data bits, even parity, 2 
stop bits). 
 
Click [Change Serial Configuration] to save these changes. 
 
To update the page with the latest available parameters, click [Refresh]