Comtech EF Data LBC-4000 User Manual
Page 116

LBC-4000 L-Band Up/Down Converter System with Ethernet
Revision 2
Serial-based Remote Product Management
MN-LBC4000A
7–14
Parameter
Type
Command
(Instruction Code
and
Qualifier)
Arguments for
Command or
Response to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes between
48 and 57)
Response to Command
(Target to controller)
Query
(Instruction Code
and qualifier)
Response to query
(Target to controller)
12VDC1_xx’cr’
08VDC1_xx’cr’
05VDC1_xx’cr’
12VDC2_xx’cr’
08VDC2_xx’cr’
05VDC2_xx’cr’
REFLD_xx’cr’
IFLOA_xx’cr’
RFLOA_xx’cr’
TEMPA_xx’cr’
IFLOB_xx’cr’
RFLOB_xx’cr’
TEMPB_xx’cr’’lf’
12 VDC #1 Fault.
8 VDC #1 Fault.
5 VDC #1 Fault.
12 VDC #2 Fault.
8 VDC #2 Fault.
5 VDC #2 Fault.
Ref Osc. Lock Detect Fault.*
Conv A IFLO Lock Detect Fault.
Conv A RFLO Lock Detect Fault.
Conv A Over Temperature Fault.
Conv B IFLO Lock Detect Fault.
Conv B RFLO Lock Detect Fault.
Conv B Over Temperature Fault.
(see Description of
Arguments for details)
*Note: REFLD is only returned if an external reference is
present.
Retrieve
Configuration Status
N/A 186
bytes
alphanumeric
Query only.
Used to Query the Configuration Status of the unit in the form
RCS_ :
N/A
RCS_
RCS_
x….x
(see Description of
Arguments for details)
FRE_A_01694.765
ATT_A_03.00
TX_A_ON
SLP_A_0.0
ONL_A_ON
FRE_B_11444.765
ATT_B_15.00
RX_B_ON
SLP_B_0.0
ONL_B_ON
RED_OFF
AFR_ON
EXT_NO
REF_087
REM_YES
COMM_RS-232
ADD_0001
BR_9600
FMT_8-N-1
Conv A frequency
Conv A attenuation
Conv A mute state
Conv A slope adj.
Conv A on/offline
Conv B frequency
Conv B attenuation
Conv B mute state
Conv B slope adj.
Conv B on/offline
Conv redundancy
auto flt recovery
external ref.
ref osc adjust
remote mode
remote interface
remote address
remote baud rate
remote data format