beautypg.com

Comtech EF Data LBC-4000 User Manual

Page 113

background image

LBC-4000 L-Band Up/Down Converter System with Ethernet

Revision 2

Serial-based Remote Product Management

MN-LBC4000A

7–11

Parameter

Type

Command

(Instruction Code

and

Qualifier)

Arguments for

Command or

Response to Query

Description of Arguments

(Note that all arguments are ASCII numeric codes between

48 and 57)

Response to Command

(Target to controller)

Query

(Instruction Code

and qualifier)

Response to query

(Target to controller)

Configure Mute Mode CMM_ 5

bytes,

alpha

Command or Query.
Turns the mute mode ON or OFF.
When mute mode is OFF (default), the unit will mute upon
changing RF frequency. When mute mode is ON, the unit will
remain whatever its mute state upon changing RF frequency: In
the form CMM_y_xxx'cr''lf'] where:

y = ‘A’ (Converter A) or ‘B’ (Converter B)
xxx = ON (mute) or OFF (unmute)

Example: CMM_A_OFF (Unmutes Converter A)

Same as command

CMM_y_

CMM_y_xxx

(see Description of
Arguments for details)

Concise
Maintenance Status

N/A

85 bytes numeric

Query only.
Used to Query the Maintenance Status of the unit in concise
format, in the form
CMS_aaa.abbb.bccc.cddd.deee.efff.fggg.ghhh.hiii.ijjj.jkkk.klll.lm
mm.mnnn.nooo.oppp.pqqq.q’cr’’lf’ where:

aaa.a = 12 VDC supply #1 in volts
bbb.b = 8 VDC supply #1 in volts
ccc.c = 5 VDC supply #1 in volts
ddd.d = 12 VDC supply #2 in volts
eee.e = 8 VDC supply #2 in volts
fff.f= 5 VDC supply #2 in volts
ggg.g = Ref Osc tuning voltage in volts
hhh.h = Converter A IFLO tuning voltage in volts
iii.i= Converter A RFLO tuning voltage in volts
jjj.j = Converter A Input Power in dBm (Reserved
for future use)
kkk.k = Converter A Output Power in dBm (Reserved for

future use)

lll.l= Converter A temperature in degrees C
mmm.m = Converter B IFLO tuning voltage in volts
nnn.n= Converter B RFLO tuning voltage in volts
ooo.o = Converter B Input Power in dBm (Reserved for

future use)

ppp.p = Converter B Output Power in dBm (Reserved for

future use)

qqq.q = Converter B temperature in degrees C

N/A

CMS_

CMS_
x….x

(see Description of
Arguments for details)