Updating Firmware
MN-LBC4000A
4–3
times to get to the top‐level display if not visible. Additionally, review the information
provided on the UTILITY Æ FIRMWAREÆ INFO Æ IMAGE#1 or IMAGE#2 screens.
• On the user PC – Use the terminal emulator program to log in to the LBC‐4000, and then
use Serial Remote Control to obtain, and make note of, the firmware information:
Type (without the quotes) “<0/FRW?
LBC‐4000 for its Firmware Number and Release Version.
See Chapter 6. SERIAL‐BASED REMOTE PRODUCT MANAGEMENT for
information and instructions on using Serial Remote Control.
• On the user PC – Use the LBC‐4000 Web Server Interface.
Use a Web browser (e.g., Internet Explorer)
to log in to the LBC‐4000 Web Server
Interface
and
review
the
Firmware
Information section of the ‘Config | Utility’
page. There, make note of the firmware
loads:
See Chapter 5. ETHERNET‐BASED REMOTE PRODUCT MANAGEMENT for
information and instructions on using the LBC‐4000 Web Server Interface.
2. Next, create a temporary folder (subdirectory) on the user PC for the firmware archive
download.
• Drive letter ‘c:’ is used in these examples. Any valid, writable drive letter can be
used.
• Typical for all tasks: Type the command without quotes, and then press Enter to
execute.
There are several ways the user may use create a temporary folder on a Windows‐based PC:
A. Use the Windows Desktop to create and rename the temporary folder.
• Right‐click anywhere on the desktop to open the popup submenu, and then select
New > Folder to create the new, temporary folder on the desktop.
• Right‐click on the new folder and then select ‘Rename’ from the popup submenu.
Rename this folder to "temp" or some other convenient, unused name.