LBC-4000 L-Band Up/Down Converter System with Ethernet

Revision 2

Updating Firmware

MN-LBC4000A

4–10

Using  the  LBC‐4000  Web  Server  Interface  –  Using  the  ‘Next  Reboot  Image  drop‐

down  menu  on  the    ‘Config  |  Utility’  page,  select  Latest1,  or  2,  and  then  click 
[Submit].  

 
 
 

By default, the unit will boot from the Slot storing the firmware version number that 
has the latest date (Next Reboot Image: Latest). ‘Next Reboot Image’ may also be 
set to force the unit to boot up using either firmware image loaded in Slot 1 or Slot 
2
. 
 

B. Reboot the LBC‐4000: 

 

• On the LBC‐4000 Web Server Interface ‘‘Config | Utility’ page, click [Reboot Now] in 

the  Perform  Soft  Reboot  section  of  the  page  to  reboot  the  LBC‐4000  using  the 
Current Active Firmware Image. Wait while the LBC‐4000 reboots. 
 

Verify  the  new  firmware  version  has  booted  by  observing  the  firmware  version 

number  displayed  on  the  Converter  front  panel  (where  X.X.X  represents  the 
properly transferred firmware version number), for example: 

LBC-4000

Ver: X.X.X SN:XXXXXXXXX

 

5. To load the second image, repeat steps 2 through 4
 

The  LBC‐4000  is  now  operating  with  its  latest  firmware.  The  firmware 
update process is now complete.