Updating Firmware
MN-LBC4000A
4–10
• Using the LBC‐4000 Web Server Interface – Using the ‘Next Reboot Image’ drop‐
down menu on the ‘Config | Utility’ page, select Latest, 1, or 2, and then click
[Submit].
By default, the unit will boot from the Slot storing the firmware version number that
has the latest date (Next Reboot Image: Latest). ‘Next Reboot Image’ may also be
set to force the unit to boot up using either firmware image loaded in Slot 1 or Slot
2.
B. Reboot the LBC‐4000:
• On the LBC‐4000 Web Server Interface ‘‘Config | Utility’ page, click [Reboot Now] in
the Perform Soft Reboot section of the page to reboot the LBC‐4000 using the
Current Active Firmware Image. Wait while the LBC‐4000 reboots.
• Verify the new firmware version has booted by observing the firmware version
number displayed on the Converter front panel (where X.X.X represents the
properly transferred firmware version number), for example:
LBC-4000
Ver: X.X.X SN:XXXXXXXXX
5. To load the second image, repeat steps 2 through 4.
The LBC‐4000 is now operating with its latest firmware. The firmware
update process is now complete.