B.3.4 gain offset for redundant operations – Comtech EF Data LBC-4000 User Manual

Page 137

background image

LBC-4000 L-Band Up/Down Converter System with Ethernet

Revision 2

Appendix B

MN-LBC4000A

 

B–7

B.3.4

Gain Offset for Redundant Operations

Once  redundancy  has  been  enabled,  the  Ofst  (Gain  Offset)  command,  available  from  the 
Configure: Conv‐A Æ Atten/Slope submenu, allows gain offset compensation in order for you 
to match gain between the two converters.  
 

Gain Offset is set at installation only. In operation, the normal attenuation setting 
should be used. 

The procedure to set the Gain Offset parameters for redundant operation is as follows: 
 

Step

Task

1

Monitor output signal level on power meter / spectrum analyzer.

2

Enable Redundancy on converter (CONFIG Æ REDUND Æ STATE=Enable).

3

Put converter into “Manual” Redundancy Mode (CONFIG Æ REDUND Æ MODE=Manual).

4

Force Converter B online (CONFIGÆREDUNDÆFrcBkup=YES) and measure output .

5

Force Converter A online (SELECT: CONFIGÆREDUNDÆFrcBkup=YES) and then, using the SELECT:
CONFIG
Æ Conv-A menu:

CONFIG CnvA: Ofst=+0.0dB

Atten=00.00dB Slope=0.0


Adjust Ofst (Gain Offset) by first using the [

][] arrow keys to select the Gain Offset digit to edit, and

then the [

][] arrow keys to change that value.

Once the Gain Offset output value matches Converter B, press [ENT].

6

Repeat Steps 4 and 5 until output levels track.

7

Return unit to desired redundancy state.