beautypg.com

4 config: refadj (reference oscillator adjustment), 5 config: spect-inv (spectrum inversion) – Comtech EF Data LBC-4000 User Manual

Page 68

background image

LBC-4000 L-Band Up/Down Converter System with Ethernet

Revision 2

Front Panel Operation

MN-LBC4000A

5–12

5.2.1.4 CONFIG: REFADJ (Reference Oscillator Adjustment)

Reference frequency
Adjustment = 087

 
The reference oscillator adjustment may be manipulated with this menu. Use the [][] arrow 
keys  to  select  a  digit  to  edit,  and  then  the  [][]  arrow  keys  to  change  its  value.  Press  [ENT] 
when done. 
 
The default Reference Frequency tuning adjustment is 087, with allowable values from 0 to 255.  
 
When  an  external  reference  oscillator  is  connected  and  set  to  10  MHz  the  following  screen 
appears: 
 

EXTERNAL 10 MHZ
REFERENCE PRESENT

 
When  an  external  reference  oscillator  is  connected  and  set  to  5  MHz  the  following  screen 
appears: 
 

EXTERNAL 5 MHZ
REFERENCE PRESENT

 
When an external reference oscillator is connected and set to other than 5 MHz or 10 MHz the 
following screen appears: 
 

EXTERNAL REFERENCE FREQ
MUST BE 5/10 MHz

5.2.1.5 CONFIG: SPECT-INV (Spectrum Inversion)

Spectrum Inversion:
ConvA=NRM ConvB=INV

 
To set Spectrum Inversion operation: Use the [][] arrow keys to select ConvA or ConvB, and 
then use the [][] arrow keys to toggle the parameter as NRM (Normal) or INV (Invert). Press 
[ENT] when done.