Comtech EF Data LBC-4000 User Manual
Page 118

LBC-4000 L-Band Up/Down Converter System with Ethernet
Revision 2
Serial-based Remote Product Management
MN-LBC4000A
7–16
Parameter
Type
Command
(Instruction Code
and
Qualifier)
Arguments for
Command or
Response to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes between
48 and 57)
Response to Command
(Target to controller)
Query
(Instruction Code
and qualifier)
Response to query
(Target to controller)
Retrieve
Utility Status
N/A
98 bytes
alphanumeric
Query only.
Used to Query the utility features of the unit in the form RUS_
where:
TIME=hh:mm:ss
DATE=mm/dd/yy
FSDA=xxxx (Reserved for future use)
FSDB=xxxx (Reserved for future use)
BVFD=yyy
SCRT=zzz
BULK=FW9965X (where X is the revision letter)
M&C =FW9966X (where X is the revision letter)
FPGA=FW9967X (where X is the revision letter)
N/A
RUS_
RUS_
x….x
(see Description of
Arguments for details)
Set Auto/Manual
Redundancy Mode
SAM_ 1
byte
alphanumeric
Command and Query.
Used to set or get status of Redundancy to either Manual or
Automatic mode in the form SAM_x where:
x = a (if chassis is in Automatic Redundancy mode) or
m (if chassis is in Manual Redundancy mode)
Same as command
SAM_
SAM_
(see Description of
Arguments for details)
Summary Alarm
Status
N/A 2
bytes,
alpha
Query only.
Used to Query the status of the Summary Fault Relay in the
form SAS_xx where:
xx = OK or FT
Example: SAS_OK
N/A
SAS_
SAS_x
(see Description of
Arguments for details)
Remote Baud Rate
SBR_ 4
bytes
Command or Query.
Used to set or query the serial baud rate in the form SBR_xxxx
where:
xxxx = remote baud rate as follows:
1200 = 1200 baud
2400 = 2400 baud
4800 = 4800 baud
9600 = 9600 baud
19K2 = 19200 baud
38K4 = 38400 baud
Same as command
SBR_
SBR_xxxx
(see Description of
Arguments for details)
Remote Address
SPA_ 4
bytes,
numeric
Command or Query.
Used to set or query the physical address in the form SPA_xxxx
where:
xxxx = Set Physical Address-between 0001 to 9999.
Resolution=0001
Example: SPA_0412
Same as command
SPA_
SPA_xxxx
(see Description of
Arguments for details)