4 utility – Comtech EF Data LBC-4000 User Manual

Page 71

background image

LBC-4000 L-Band Up/Down Converter System with Ethernet

Revision 2

Front Panel Operation

MN-LBC4000A

5–15

A total of 100 faults can be stored in memory as they occur, and the faults are date and time 
stamped. The stored faults remain in memory until a CLEAR‐ALL command is entered. When the 
number of faults reaches 100, the 100

th

 fault will display an error (

ER

)

FAULTS: STORED

Æ CLEAR-ALL

Clear all stored Faults

No Yes

 
Upon selecting CLEAR‐ALL, you are prompted to choose No or Yes. Use the [][] arrow keys 
to select your choice, and then press [ENT].  
 
By  selecting  Yes,  the  event  log  is  cleared  and  you  are  then  returned  to  the  previous  menu.  
However, if there are faults present on the unit at this time, they will be re‐time‐stamped, and 
new log entries will be generated. 

5.2.4

UTILITY

TIME DISP FIRMWARE AID
LAMPTEST RELAY SCRSAVER

 
Use the [][] arrow keys to select from the submenu choices shown, and then press [ENT].  
 
The following table identifies each submenu available from the UTILITY menu branch – typical 
for Converter Unit A or Unit B – its content section in this chapter, and functional description of 
each submenu: 
 

Submenu

Sect

Functional Description

TIME

5.2.4.1

Edits the date and Real-Time Clock time settings

DISP

5.2.4.2

Adjusts the brightness level of the Vacuum Fluorescent Display (VFD)

FIRMWARE

5.2.4.3

Displays and selects the installed internal firmware images

AID

5.2.4.4

Use to enter an 48-character Application ID string (2 lines, 24 characters/line)

LAMP-TEST

5.2.4.5

Runs a diagnostic test on each of the two sets of five front panel Light-Emitting
Diodes (LEDs

RELAY

5.2.4.6

Selects Fault Relay Logic

SCRSAVER

5.2.4.7

Screen saver