5.2.1.1 CONFIG: CONV-A or CONV-B (Converter Unit A or Unit B)

CONFIG CnvX: (IF=YYYMHz)
FREQ/MUTE ATTN/SLOPE

 
Where ‘X’ is the selected converter – CnvA (Converter Unit A) or CnvB (Converter Unit B) – and 
‘YYY’  indicates  its  operating  frequency  (70  or  140  MHz),  use  the  [][]  arrow  keys  to  select 
FREQ/MUTE or ATTEN/SLOPE, and then press [ENT].  

CONFIG CnvA or CnvB

Æ FREQ/MUTE

CONFIG CnvX: CMM=ON
Frq=01980.000MHz Rx=ON

 
To select the CMM (Configuration Mute Mode): Use the [][] arrow keys to select the mute 
parameter, and then use the [][] arrow keys to select ON or OFF
 
Use  the  [][]  arrow  keys  to  select  the  parameter  to  edit  –  CMMFreq,  or  –  depending  on 
whether the unit is an Upconverter or Downconverter – Rx or Tx.  
 
To set the converter’s operating frequency: Use the [][] arrow keys to select a digit to edit, 
and  then  use  the  [][]  arrow  keys  to  change  that  digit.  Repeat  for  all digits until the desired 
frequency has been defined. 
 
To select the Tx/Rx mute status: Use the [][] arrow keys to select the mute parameter, and 
then use the [][] arrow keys to select ON or OFF.  
 
Press [ENT] when done. 

CONFIG CnvA or CnvB

Æ ATTEN/SLOPE

When ATTEN/SLOPE is selected for CnvA

CONFIG CnvA: Ofst=+0.0dB
Atten=00.00dB Slope=0.0


When ATTEN/SLOPE is selected for CnvB:  

CONFIG CnvB:
Atten=00.00dB Slope=0.0

 
For either, use the [][] arrow keys to select the parameter to edit – Atten or Slope.  
 
To set the converter’s attenuation: Use the [][] arrow keys to select a digit to edit, and then 
use the [][] arrow keys to change its value.  
 
To  set  the  converter’s  slope  value:  Use  the  [][]  arrow  keys  to  select,  in  0.1  increments,  a 