LBC-4000 L-Band Up/Down Converter System with Ethernet

Revision 2

Serial-based Remote Product Management

MN-LBC4000A

7–15

Parameter

Type

Command

(Instruction Code

and

Qualifier)

Arguments for

Command or

Response to Query

Description of Arguments

(Note that all arguments are ASCII numeric codes between

48 and 57)

Response to Command

(Target to controller)

Query

(Instruction Code

and qualifier)

Response to query

(Target to controller)

Redundancy Mode

RED_ 3

bytes

alphanumeric

Command and Query.
Used to set the chassis in redundancy mode or to query status
of redundancy in the form RED_xxx where:

xxx = ON (if redundancy is enabled) or
OFF(if redundancy is disabled)

Same as command

RED_

RED_
(see Description of
Arguments for details)

Remote Mode

REM_ 1

byte,

value 0 or 1

Command or Query
Sets to remote mode or local mode in the form REM_x where:

x = 0 (local mode) or 1 (remote mode)

Same as command

REM_

REM_x
(see Description of
Arguments for details)

Retrieve Module
Equipment Type

N/A 12

bytes,

alphanumeric

Query only.
The unit returns a string indicating the frequency of the selected
module and the module type (Up-Link or Down-Link) in the form
RET_x_ where:

x = ‘A’ or ‘B’

Example: RET_A_140_DL or RET_B_070_UL

N/A

RET_x_

RET_x….x

(see Description of
Arguments for details)

Retrieve Equipment
Type

N/A 22

bytes,

alphanumeric

Query only.
The unit returns a string indicated the Model Number and the
value of internal software revision installed
Example: RET_LBC-4000 VER:1.2.1

N/A

RET_

RET_x….x

(see Description of
Arguments for details)

Retrieve
Maintenance Status

N/A 203

bytes,

alphanumeric

Query only.

Used to Query the maintenance status of the unit in the form
RMS_’cr’ :

N/A

RMS_

RMS_
x….x

(see Description of
Arguments for details)

12VT1=xxx.x’cr’
08VT1=xxx.x’cr’
05VT1=xxx.x’cr’
12VT2=xxx.x’cr’
08VT2=xxx.x’cr’
05VT2=xxx.x’cr’
VTREF=xxx.x’cr’
IFLOA=xxx.x’cr’
RFLOA=xxx.x’cr’
PIN_A=xxx.x’cr’.
POUTA=xxx.x’cr’
TEMPA=xxx.x’cr’
IFLOB=xxx.x’cr’
RFLOB=xxx.x’cr’
PIN_B=xxx.x’cr’
POUTB=xxx.x’cr’
TEMPB=xxx.x’cr’’

12 VDC Supply #1 in volts.

8 VDC Supply #1 in volts.
5 VDC Supply #1 in volts.
12 VDC Supply #2 in volts.
8 VDC Supply #2 in volts.
5 VDC Supply #2 in volts.
Ref Osc tuning voltage in volts.
Conv A IFLO tuning voltage, V.
Conv A RFLO tuning voltage, V.
Conv A Input power in dBm.
Conv A Output power in dBm.
Conv A temperature in deg C.
Conv B IFLO turning voltage, V.
Conv B RFLO tuning voltage, V.
Conv B Input power in dBm.
Conv B Output power in dBm.
Conv B temperature in deg C