LBC-4000 L-Band Up/Down Converter System with Ethernet
Revision 2
Front Panel Operation
MN-LBC4000A
5–10
To edit the SNMP Read Community string: Use the [←][→] arrow keys to select a
character to edit, and then use the [↑][↓] arrow keys to change that character.
Only the first 20 characters on the bottom line are available.
All printable ASCII characters are available with the exception of the backslash (ASCII
code 92) and ~ (ASCII code 126).
Press [ENT] once the string has been composed. All trailing spaces are removed from the
Read Community string upon entry.
When WRITE is selected:
Write Community:
Private
To edit the SNMP Write Community string: Use the [←][→] arrow keys to select a
character to edit, and then use the [↑][↓] arrow keys to change that character.
Only the first 20 characters on the bottom line are available.
All printable ASCII characters are available with the exception of the backslash (ASCII
code 92) and ~ (ASCII code 126).
Press [ENT] once the string has been composed. All trailing spaces are removed from the
Write Community string upon entry.
When TRAP is selected:
Trap Community:
comtech
To edit the SNMP Traps Community string: Use the [←][→] arrow keys to select a
character to edit, and then use the [↑][↓] arrow keys to change that character.
Only the first 20 characters on the bottom line are available.
All printable ASCII characters are available with the exception of the backslash (ASCII
code 92) and ~ (ASCII code 126).
Press [ENT] once the string has been composed. All trailing spaces are removed from the
Trap Community string upon entry.