7.2.2.2 Target Address

Up  to  9,999  devices  can  be  uniquely  addressed;  in  EIA‐485  applications,  the  permissible  range  of  values  is  1  to  9999.  The  address  is 
programmed into a Target unit using the remote control port. 
 
Each block converter module has its own address: 
 

Module

Address

LBC-4000 Base

Block Converter A

Base + 1

Block Converter B

Base + 2

 
If several devices share an EIA‐485 bus, it must be noted that the LBC‐4000 will require three addresses, and should be spaced apart 
accordingly. 
 

The Controller sends a packet with the address of a Target – the destination of the packet. When the Target responds,
the address used is the same address, to indicate to the Controller the source of the packet. The Controller does not
have its own address.

 

7.2.2.3 Address Delimiter

This is the “forward slash” character '' (ASCII code 47). 

7.2.2.4 Instruction Code

This is a three‐character alphabetic sequence that identifies the message subject. 
 
Wherever  possible,  the  instruction  codes  have  been  chosen  to  have  some  significance  –  e.g.,  FRE  for  Operating  FREquency,  IPA  for 
Management IP Address, etc. This aids in the readability of the message, should it be displayed in its raw ASCII form. 
 
Upper case and lower case alphabetic characters may be used (‘A’ to ‘Z’ and ‘a’ to ‘z’, ASCII codes 65‐90 and 97‐172).