B.3.2 config (configuration) menu – Comtech EF Data LBC-4000 User Manual

Page 135

background image

LBC-4000 L-Band Up/Down Converter System with Ethernet

Revision 2

Appendix B

MN-LBC4000A

 

B–5

B.3.2

CONFIG (Configuration) Menu

   

CONV-A CONV-B REMOTE

REDUND REFADJ SPECT-INV

 
Use the [][] arrow keys to select from the submenu choices shown, and then press [ENT]
Each  submenu  available  from  the  Configuration  menu  branch  is  typical  for  Converter  A  or 
Converter B. 
 
For quick reference, a description of each of the submenu branches follows, and the section in 
this appendix (as shown in bold) that addresses use relevant to Redundancy operation. 
 
Otherwise,  see  Chapter  5.  FRONT  PANEL  OPERATION  for  complete  information  on  the 
functionality of these features: 
 

Submenu

Ch. 5 / App. B Sect

Description

CONV-A
CONV-B

5.2.1.1

B.3.4

(Converter Unit A or B) Displays the current configuration
of the selected converter, including the frequency,
attenuation, and slope.

REMOTE

5.2.1.2

(Remote Control) Defines whether the unit is being controlled
locally or remotely, and identifies the unit address, interface
type, and rate and format of the baud parameters.

REDUND

5.2.1.3

B.3.3

(Redundancy) Identifies the redundancy state and mode

REFADJ

5.2.1.4

(Reference Oscillator Adjustment) Adjusts the reference
oscillator.

SPECT-INV

5.2.1.5 (Spectrum

Inversion)