2 monitor – Comtech EF Data LBC-4000 User Manual

Page 69

background image

LBC-4000 L-Band Up/Down Converter System with Ethernet

Revision 2

Front Panel Operation

MN-LBC4000A

5–13

5.2.2

MONITOR

Use the[][] arrow keys to view monitor menu choices shown.  
 
For all read‐only Monitor displays, press [ENT] or [CLR] to return to the previous menu. 
 
The following table identifies each read‐only display available from the Monitor menu branch, 
including a sample screen and a functional description of the display: 
 

Submenu

Example

Description

Conv-A

Monitor A: iflo=08.2
rflo=01.6 tp=+32.1

For Converter Unit A or B: The operating
parameters for the selected Up/Down-
converter IDU are shown, where:

iflo = IF Lockout
rflo = RF Lockout
tp = Operating Temp (°C)

Conv-B

Monitor B: iflo=08.1
rflo=01.6 tp=+30.2

RefOsc

MON Ref Osc:
Vtune=04.7

The raw voltage of the voltage tuning monitor
is shown.

Note: This display is used for debugging
purposes only.

PwrSupA

Monitor PS A: 12V=12.3
8V=08.2 5V=05.3

Where ‘X’ denotes Power Supply ‘A’ or ‘B’:
The 12V, 8V, and 5V values for the selected
power supply are shown.

PwrSupB

Monitor PS B: 12V=12.2
8V=08.1 5V=05.3