LBC-4000 L-Band Up/Down Converter System with Ethernet

Revision 2

Updating Firmware

MN-LBC4000A

4–9

Once the Management IP Address is known – use Command‐line to PING: Type “ping 

xxx.xxx.xxx.xxx”  at  the  Command‐line  prompt  (where  ‘xxx.xxx.xxx.xxx’  is  the  unit 
Management IP Address).  

 

The  response  should  confirm  whether  the  unit  is  properly  connected  and 
communicating. 

 
2. Use Command‐line to transfer (FTP) the files from the user PC to the LBC‐4000: 

 
• Type  "ftp  xxx.xxx.xxx.xxx"  (where  ‘xxx.xxx.xxx.xxx’  denotes  the  unit  Management  IP 

Address). 
 

• Enter the Admin User Name (there will be no prompt for a password) to complete login. 

 

• Type “bin” to set the binary transfer mode. 

 

• Type "prompt" and then type "hash" to facilitate the file transfers. 

 

• Type  "put  FW‐0020503x_LBC4000_Ethernet_#_#_#.bin  bulk:"  (where  ‘x’  denotes  the 

revision  letter,  and  #_#_#  denotes  the  FW  version)  at  the  Command‐line  prompt, 
without  quotes,  to  begin  the  file  transfer.  The  destination  “bulk:”  must  be  all  lower‐
case. 

 

Approximately one minute is required to transfer the file. 

 

• Next, the PC should report that the file transfer has occurred. The VFD will first display 

Programming App Flash … Please wait”, and then “Programming main FPGA … Please 
wait
”. 

 

In the event you receive the “Connection closed by remote host.” message, 
wait  another  minute  before  continuing.  The  LBC‐4000  update  sometimes 
takes longer than the FTP client allows.
 

• Type "bye" to terminate the FTP session, and then close the Command‐line window. 

 
3. Use  the  LBC‐4000  Serial  Interface,  or  review  the  Firmware  Information  section  of  the 

LBC‐4000 Web Server Interface ‘Config | Utility’ page to verify that the PC‐to‐Unit FTP file 
transfer was successful. 

 

4. Use the LBC‐4000 Web Server Interface to select the firmware and reboot the unit: 
 

A. Select the desired image (boot) Slot: 

 

Using  the  LBC‐4000  Front  Panel  –  Select  the  desired  image  to  boot  from  the 

UTILITY

Æ FIRMWAREÆ SELECT

screen, and then press [ENT]