Comtech EF Data LBC-4000 User Manual
Page 112
![background image](https://www.manualsdir.com/files/778945/content/doc112.png)
LBC-4000 L-Band Up/Down Converter System with Ethernet
Revision 2
Serial-based Remote Product Management
MN-LBC4000A
7–10
Parameter
Type
Command
(Instruction Code
and
Qualifier)
Arguments for
Command or
Response to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes between
48 and 57)
Response to Command
(Target to controller)
Query
(Instruction Code
and qualifier)
Response to query
(Target to controller)
Concise
Alarm Status
N/A
13 bytes numeric
Query only.
Used to Query the Alarm Status of the unit, in the form
CAS_abcdefghijklm’cr’’lf’, where:
a = 1 if 12VDC #1 Fault, else 0.
b = 1 if 8VDC #1 Fault, else 0.
c = 1 if 5VDC #1 Fault, else 0.
d = 1 if 12VDC #2 Fault, else 0.
e = 1 if 8VDC #2 Fault, else 0.
f = 1 if 5VDC #2 Fault, else 0.
g = 1 if REF LD Fault, else 0.
h = 1 if IFLO A Fault, else 0.
i = 1 if RFLO A Fault, else 0.
j = 1 if TEMP A Fault, else 0.
k = 1 if IFLO B Fault, else 0.
l = 1 if RFLO B Fault, else 0.
m = 1 if TEMP B Fault, else 0.
N/A
CAS_
CAS_x….x
(see Description of
Arguments for details)
Concise
Configuration Status
N/A
52 bytes
numeric
Query only.
Used to query the summarized version of RCS, in the form
CCS_aaaaa.aaabb.bbcd.defffff.fffgg.gghi.ijklmnnnopqqqqrs
where:
aaaaa.aaa = Conv A frequency in MHz
bb.bb = Conv A attenuation in dB
c = Conv A mute state, 0 = 7–10nmated, 1 = muted
d.d = Conv A slope adjust
e = Conv A online/offline (redundancy)
fffff.fff = Conv B frequency in MHz
gg.gg = Conv B attenuation in dB
h = Conv B mute state, 0 = unmuted, 1 = muted
i.i = Conv B slope adjust
j = Conv B online/offline (redundancy)
k = Converter redundancy
l = auto fault recovery, 1=auto, 0=manual
m = external ref present, 0=no ext ref, 1=present
nnn = internal ref. Oscillator adjust (000-255)
o = remote mode, 1=remote, 0=local
p = remote interface, 0=EIA-232, 1=EIA-485
qqqq = remote address (0-9999)
r = remote baud rate (0=38400, 1=19200, 2=9600,
3=4800, 4=2400, 5=1200)
s = remote data format (0 = 8N1, 1=7E2, 2=7O2)
N/A
CCS_
CCS_
x….x
(see Description of
Arguments for details)