Comtech EF Data LBC-4000 User Manual
Page 95
LBC-4000 L-Band Up/Down Converter System with Ethernet
Revision 2
Ethernet-based Remote Product Management
MN-LBC4000A
6–19
Converter A / Converter B
•
Frequency in MHz:
Enter an operating RF Frequency (if the converter is a Ku‐Band down
converter) in the range of 10950 to 12750 MHz. Otherwise, this field will display as N/A.
•
Attenuation (dB): Enter a valid attenuation level (00.00 to 20.00 dB) in 0.25 dB steps.
•
Attenuation Offset (ConvA page only): Enter a valid value, in dB, for the attenuation offset.
Click [Change Configuration] to save these changes. If you wish to revert to the previously
assigned parameters, click [Reset] instead (ConvB page only).
Mute
Use the drop‐down menu to select Configuration Mute Mode as On or Off, and then click
[Change].
Carrier Mute Mode
Use the drop‐down menu to select the Carrier Mute function as On or Off, and then click
[Change].
Slope
Enter a slope value (0.0 to 1.0) in 0.1 steps. Click [Change] when done.
Spectrum Inversion
Use the drop‐down menu to select the Spectrum Inversion function as INV or NRM (Normal), and
then click [Change].
Click [Submit SNMP] to save these changes.