Comtech EF Data LBC-4000 User Manual
Page 121
LBC-4000 L-Band Up/Down Converter System with Ethernet
Revision 2
Serial-based Remote Product Management
MN-LBC4000A
7–19
Parameter
Type
Command
(Instruction Code
and
Qualifier)
Arguments for
Command or
Response to Query
Description of Arguments
(Note that all arguments are ASCII numeric codes between
48 and 57)
Response to Command
(Target to controller)
Query
(Instruction Code
and qualifier)
Response to query
(Target to controller)
Firmware
N/A
Query
Returns firmware information for the Boot Rom, Image1 and
Image2. For example:
Boot:
FW-0020506;1.1.1;06/07/11
Bulk1:
FW-0020503;1.2.1;06/15/11
FW-0020504;1.1.1;06/15/11
FW-0020505;1.1.1;06/07/11
Bulk2:
FW-0020503;1.2.1;06/17/11
FW-0020504;1.1.1;06/15/11
FW-0020505;1.1.1;06/07/11
FRM_
FRM_
Part Number
N/A
Various 1-96 bytes
Query only.
Returns the Comtech EF Data part number for the Unit, Slot A
or Slot B. This part number is the DOTCODE at the time it was
manufactured. The DOTCODE may be up to 96 printable ASCII
characters long.
<1/PNM_U_ returns the Units Part Number
<1/PNM_A_ returns Slot A Part Number
<1/PNM_B_ returns Slot B Part Number
N/A
PNM_x_
PNM=x.....x