Comtech EF Data SFC1800A User Manual
Page 97

SFC1800A Synthesized Frequency Upconverter
Appendix B
TM111 – Rev. 1.0
B-
5
freq_70mhz(1),
freq_140mhz(2)
}
MAX-ACCESS
read-only
STATUS
current
DESCRIPTION
"Shows converter frequency type"
::= { radConverterStatus 7 }
radConverterReferenceType OBJECT-TYPE
SYNTAX
INTEGER {
internal(1),
external(2)
}
MAX-ACCESS
read-only
STATUS
current
DESCRIPTION
"Shows converter reference type"
::= { radConverterStatus 8 }
radConverterMajorAlarmStatus OBJECT-TYPE
SYNTAX
AlarmByteType
MAX-ACCESS
read-only
STATUS
current
DESCRIPTION
"A bit field. On startup, the agent initializes this
to the value '00000000'B
Bit 0 = LO Fault
Bit 1 = Signal Fault
Bit 2-7 = Spares
0 = Pass, 1 = Fail"
::= { radConverterStatus 9 }
radConverterMinorAlarmStatus OBJECT-TYPE
SYNTAX
AlarmByteType
MAX-ACCESS
read-only
STATUS
current
DESCRIPTION
"A bit field. On startup, the agent initializes this to
the value '00000000'B
Bit 0 = RF Dtect Fault
Bit 1 = IF Dtect Fault
Bit 2-7 = Spares
0 = Pass, 1 = Fail"
::= { radConverterStatus 10 }
radConverterLatchedMajorAlarmStatus OBJECT-TYPE
SYNTAX
AlarmByteType
MAX-ACCESS
read-only
STATUS
current
DESCRIPTION
"A bit field. On startup, the agent initializes this
to the value '00000000'B.
Bit 0 = LO Fault
Bit 1 = Signal Fault
Bit 2-7 = Spares
0 = Pass, 1 = Fail"
::= { radConverterStatus 11 }
radConverterLatchedMinorAlarmStatus OBJECT-TYPE
SYNTAX
AlarmByteType
MAX-ACCESS
read-only
STATUS
current
DESCRIPTION
"A bit field. On startup, the agent initializes this to
the value '00000000'B.