beautypg.com

Comtech EF Data SFC1800A User Manual

Page 97

background image

SFC1800A Synthesized Frequency Upconverter

Appendix B

TM111 – Rev. 1.0

B-

5

freq_70mhz(1),

freq_140mhz(2)

}

MAX-ACCESS

read-only

STATUS

current

DESCRIPTION

"Shows converter frequency type"

::= { radConverterStatus 7 }


radConverterReferenceType OBJECT-TYPE

SYNTAX

INTEGER {

internal(1),

external(2)

}

MAX-ACCESS

read-only

STATUS

current

DESCRIPTION

"Shows converter reference type"

::= { radConverterStatus 8 }


radConverterMajorAlarmStatus OBJECT-TYPE

SYNTAX

AlarmByteType

MAX-ACCESS

read-only

STATUS

current

DESCRIPTION

"A bit field. On startup, the agent initializes this

to the value '00000000'B

Bit 0 = LO Fault

Bit 1 = Signal Fault

Bit 2-7 = Spares

0 = Pass, 1 = Fail"

::= { radConverterStatus 9 }


radConverterMinorAlarmStatus OBJECT-TYPE

SYNTAX

AlarmByteType

MAX-ACCESS

read-only

STATUS

current

DESCRIPTION

"A bit field. On startup, the agent initializes this to

the value '00000000'B

Bit 0 = RF Dtect Fault

Bit 1 = IF Dtect Fault

Bit 2-7 = Spares

0 = Pass, 1 = Fail"

::= { radConverterStatus 10 }


radConverterLatchedMajorAlarmStatus OBJECT-TYPE

SYNTAX

AlarmByteType

MAX-ACCESS

read-only

STATUS

current

DESCRIPTION

"A bit field. On startup, the agent initializes this

to the value '00000000'B.

Bit 0 = LO Fault

Bit 1 = Signal Fault

Bit 2-7 = Spares

0 = Pass, 1 = Fail"

::= { radConverterStatus 11 }


radConverterLatchedMinorAlarmStatus OBJECT-TYPE

SYNTAX

AlarmByteType

MAX-ACCESS

read-only

STATUS

current

DESCRIPTION

"A bit field. On startup, the agent initializes this to

the value '00000000'B.

This manual is related to the following products: