C.27 dump calibration table set (all), C.28 get current dac value (all), C.29 get dac value for frequency and gain (all) – Comtech EF Data SFC1800A User Manual
Page 130

Appendix C
SFC1800A Synthesized Frequency Upconverter
C-20
TM111 – Rev. 1.0
[ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g]
[ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g]
{End of transmission}
where:
ffff.f
{f = frequency for channel entry]
sgg.g
{s = ‘+’ or ‘-‘ : gg.g = Gain for channel entry]
C.27 Dump Calibration Table Set (All)
This command returns the contents (DAC values for all gains) of the Power Calibration Table for
the given Frequency Index. The command is as follows:
@01/DMPCALff
ff
{Index into the frequency array portion of the table}
If successful, the converter will return the following string:
[ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g]
[ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g]
[ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g]
[ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g]
[ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g] [ffff.f,sgg.g]
{End of transmission}
where:
ffff.f
{f = frequency for channel entry}
sgg.g
{s = ‘+’ or ‘-‘ : gg.g = Gain for channel entry}
C.28 Get Current DAC Value (All)
This command returns the DAC value in use for the unit’s current configuration (Values of
Frequency and Gain). The command is as follows:
@01/CURDAC
If successful, the converter will return the following string.:
DAC Value = dddd
{dddd = DAC Value}
{End of transmission}
C.29 Get DAC Value for Frequency and Gain (All)
This command returns the DAC value to be used for the given values of frequency and gain. The
command is as follows:
@01/DACFORffff.f gg.g