Opcode: <3014h> command set channel, A.5 switch commands – Comtech EF Data SFC1800A User Manual
Page 90

Appendix A
SFC1800A Synthesized Frequency Upconverter
A-8
TM111 – Rev. 1.0
Opcode: <3013h>
Command set gain for the given channel
<4>
<1>
Gain
Channel
-20.0 dB to +30.0 dB depending on input attenuator setting
1 - 30
Opcode: <3014h>
Command set channel
<1>
Channel
1 - 30
Opcode: <3015h>
Command set carrier control
<1>
Carrier Control
0 = Off, 1 = On
Opcode: <3016h>
Command set input attenuation
<1>
Input
Attenuation
0 - 31, Upconverter only
Opcode: <3017h>
Command set converter configuration
<1>
Converter
Config
0 = Single
1 = 1F1 Primary
2 = 1F1 Backup
3 = 1F8 Primary
4 = 1F8 Backup
Opcode: <3018h>
Command set converter alarm masks
<1>
<1>
Major Alarm
Mask
Minor Alarm
Bit 0 = LO Fault
Bit 1 = Signal Fault
Bits 2 - 7 = Spares
Bits 0 - 7 = Spares
A.5 Switch Commands
Opcode: <3030h>
Command set backup mode
<1>
Backup Mode
0 = Manual, 1 = Automatic
Opcode: <3031h>
Command force a manual backup
<1>
Prime To
Backup
1 - 8, converter must be present
Opcode: <3032h>
Command learn converter configuration
<1>
Prime To Learn
1 - 8, converter must be present
Opcode: <3033h>
Command learn all converter configurations
(No data field for this opcode)
Opcode: <3034h>
Command backup test converter configuration
<1>
Prime To Test
1 - 8, converter must be present