Comtech EF Data SFC1800A User Manual
Page 91

SFC1800A Synthesized Frequency Upconverter
Appendix A
TM111 – Rev. 1.0
A
-9
Opcode: <3035h>
Command backup test all converter configurations
(No data field for this opcode)
Opcode: <3036h>
Command set compensation control
<1>
Compensation
Control
0 = Disable, 1 = Enable (Only valid in Chain-Switching Mode)
Opcode: <3037h>
Command set converter compensation
<2>
<1>
Prime
Compensation
Prime To
Compensate
Note: Command is only valid in Chain-Switching Mode.
Binary value, one implied decimal point
1 - 8, converter must be present
Opcode: <3038h>
Command set all converter compensations
<2>
<2>
<2>
<2>
<2>
<2>
<2>
<2>
Prime 1
Compensation
Prime 2
Compensation
Prime 3
Compensation
Prime 4
Compensation
Prime 5
Compensation
Prime 6
Compensation
Prime 7
Compensation
Prime 8
Compensation
Note: Command is only valid in Chain-Switching Mode
Binary value, one implied decimal point
Binary value, one implied decimal point
Binary value, one implied decimal point
Binary value, one implied decimal point
Binary value, one implied decimal point
Binary value, one implied decimal point
Binary value, one implied decimal point
Binary value, one implied decimal point
Opcode: <3039h>
Command set converter priority
<1>
<1>
Prime Priority
Prime Number
0 - 8 (0 means not part of the backup pool)
1 - 8, converter must be present