beautypg.com

C.19 erase (all), C.20 restart (all), C.21 learn (b1: 1, b1: 8) – Comtech EF Data SFC1800A User Manual

Page 126

background image

Appendix C

SFC1800A Synthesized Frequency Upconverter

C-16

TM111 – Rev. 1.0

C.17 Set Stored Gain For a Specified Channel (S, P1: 1, P1: 8)


This command allows the user to set the Stored Gain for a specified channel. The command is as
follows:

@01/RAMGAINccsgg.g


If successful, the converter will not return a string.

C.18 Set Stored Frequency For a Specified Channel (S, P1: 1, P1: 8)


This command allows the user to set the Stored Frequency for a specified channel other than the
current one. The command is as follows:

@01/RAMFREQccffff.t


If successful, the converter will not return a string.

C.19 Erase (All)


This command allows the user to erase the Stored Status, Frequency and Gain Information the
next time the unit is reset. The command is as follows:

@01/ERASE

If successful, the converter will not return a string.

C.20 Restart (All)


This command allows the user to reset/restart the converter. The command is as follows:

@01/RESTART


If successful, the converter will not return a string.

C.21 Learn (B1: 1, B1: 8)


In a 1:1 Switch configuration, this command will cause the backup converter to ‘Learn’ about the
Prime converter.

In a 1:8 configuration, the backup converter will ‘Learn’ about the Prime converters that have a
priority >0. As the backup converter polls the Prime(s), the learning status will be output via the
serial port. The command is as follows:

@01/LEARN


A backup converter in a 1:1 Switch Configuration will return one of the following strings of
information:



Learning FAILED because the Prime gave an invalid response/Prime did not
respond/Prime's incompatible with the Backup/Prime's RF is turned off}

{End of transmission}


This manual is related to the following products: