SFC1800A Synthesized Frequency Upconverter
User Interfaces
TM111 – Rev. 1.0
4-13
CONVERTER BAND:
{C-BAND, KU-BAND}
Indicates whether the unit is a C-Band or Ku-Band
Converter. This display will match the text on the Front
Panel Overlay.
FREQUENCY TYPE:
{70 MHz, 140 MHz}
Indicates the IF type of the Converter.
SYNTHESIZER:
{MFS-1191, MFS-448, MFS-459, MFS-544, MFS-881,
MFS-474, MFS-4.47, MFS-4.59}
Displays the model number of the unit's installed
synthesizer. The frequency range of each model is
given below:
Model
IF LO
Frequency
Frequency Range
Low
High
MFS 1191
1.7 GHz
11.91GHz
12.73 GHz
MFS 448
1.225 GHz
4.48 GHz
5.355 GHz
MFS 459
1.1125 GHz 4.5925 GHz 5.2425 GHz
MFS 544
1.1125 GHz 5.4475 GHz 5.8675 GHz
MFS 881
2.0 GHz
8.81 GHz
10.68 GHz
MFS 474
1.1125 GHz
4.74 GHz
5.54 GHz
MFS 4_47
1.1125 GHz
4.47 GHz
5.34 GHz
MFS 4_59
1.1125 GHz
4.59 GHz
5.54 GHz
DEBUG MODE:
Password protected. Enables additional Menus for
debugging purposes.
LOAD DEFAULT:
Password protected. Configures the Converter with a
set of default parameters. Refer to Section 4.5 for actual
default settings.
SNMP DEFAULT:
Password protected. Configures the Converter SNMP
(Ethernet Interface) settings to default values.