Comtech EF Data SFC1800A User Manual
Page 101

SFC1800A Synthesized Frequency Upconverter
Appendix B
TM111 – Rev. 1.0
B-
9
MAX-ACCESS
read-only
STATUS
current
DESCRIPTION
"A bit field. On startup, the agent initializes this to
the value '00000000'B.
Bit 0 = LearnedFault
Bit 1 = BackupTestFault
Bit 2 = ConfigChangedFault
Bit 3-7 = Spares
0 = Pass, 1 = Fail"
::= { radConverterSwitchStatus 2 }
radConverterSwitchLatchedMajorAlarmStatus OBJECT-TYPE
SYNTAX
AlarmByteType
MAX-ACCESS
read-only
STATUS
current
DESCRIPTION
"A bit field. On startup, the agent initializes this
to the value '00000000'B.
Bit 0 = RelayFault
Bit 1 = Backup Fault
Bit 2 = NoBackup
Bit 3 = PollingFault
Bit 4-7 = Spares
0 = Pass, 1 = Fail"
::= { radConverterSwitchStatus 3 }
radConverterSwitchLatchedMinorAlarmStatus OBJECT-TYPE
SYNTAX
AlarmByteType
MAX-ACCESS
read-only
STATUS
current
DESCRIPTION
"A bit field. On startup, the agent initializes this to
the value '00000000'B.
Bit 0 = LearnedFault
Bit 1 = BackupTestFault
Bit 2 = ConfigChangedFault
Bit 3-7 = Spares
0 = Pass, 1 = Fail"
::= { radConverterSwitchStatus 4 }
radConverterSwitchFaultStatus OBJECT-TYPE
SYNTAX
PrimeStatusType
MAX-ACCESS
read-only
STATUS
current
DESCRIPTION
"Prime converter fault status:
Bit 0 = Prime 1
Bit 1 = Prime 2
Bit 2 = Prime 3
Bit 3 = Prime 4
Bit 4 = Prime 5
Bit 5 = Prime 6
Bit 6 = Prime 7
Bit 7 = Prime 8
0 = No Fault, 1 = Fault"
::= { radConverterSwitchStatus 5 }
radConverterSwitchRelayStatus OBJECT-TYPE
SYNTAX
PrimeStatusType
MAX-ACCESS
read-only
STATUS
current
DESCRIPTION
"Prime converter relay status:
Bit 0 = Prime 1
Bit 1 = Prime 2