Comtech EF Data SFC1800A User Manual
Page 92

Appendix A
SFC1800A Synthesized Frequency Upconverter
A-10
TM111 – Rev. 1.0
Opcode: <303Ah>
Command set all converter priorities
<1>
<1>
<1>
<1>
<1>
<1>
<1>
<1>
Prime 1 Priority
Prime 2 Priority
Prime 3 Priority
Prime 4 Priority
Prime 5 Priority
Prime 6 Priority
Prime 7 Priority
Prime 8 Priority
0 – 8 (0 means not part of the backup pool)
0 – 8 (0 means not part of the backup pool)
0 – 8 (0 means not part of the backup pool)
0 – 8 (0 means not part of the backup pool)
0 – 8 (0 means not part of the backup pool)
0 – 8 (0 means not part of the backup pool)
0 – 8 (0 means not part of the backup pool)
0 – 8 (0 means not part of the backup pool)
Opcode: <303Bh>
Command set switch alarm masks
<1>
<1>
Major Alarm
Mask
Minor Alarm
Mask
Bit 0 = Polling Fault
Bit 1 = Relay Fault
Bits 2 - 7 = Spares
Bit 0 = Learned Fault
Bit 1 = Backup Test Fault
Bits 2 - 7 = Spares