beautypg.com

Table 2-23, Critical temperature limits, Figure 2-8 – Artesyn ATCA-9405 Installation and Use (May 2014) User Manual

Page 54: Air flow graph, Setup

background image

Setup

ATCA-9405 Installation and Use (6806800M71G)

54

During the safety qualification of this blade, the following on-board locations were identified
as critical with regards to the maximum temperature during blade operation. To guarantee
proper blade operation and to ensure safety, you have to make sure that the temperatures at
the locations specified in the following table are not exceeded. If not stated otherwise, the
temperatures should be measured by placing a sensor exactly at the given locations.

If you integrate the blade in your own system, contact your local sales representative for
further safety information.

Figure 2-8

Air Flow Graph

Table 2-23 Critical Temperature Limits

Component

Thermal Design Power

Maximum Case or Junction
Temperature

Cavium CN6880 PP1

72 W

Tj = 101°C

Cavium CN6880 PP2

72 W

Tj = 101°C

DDR3 DIMM Modules

6.9 W

Tc = 85°C

PCI-Express Switch

2.9 W

Tj = 110°C

Ethernet Switch

33.5 W

Tj = 115°C