beautypg.com

4 get feature configuration, Table 8-18, Get feature configuration command – Artesyn ATCA-9405 Installation and Use (May 2014) User Manual

Page 153: Intelligent peripheral management controller

background image

Intelligent Peripheral Management Controller

ATCA-9405 Installation and Use (6806800M71G)

153

8.21.4 Get Feature Configuration

This command is used to retrieve the IPMI feature set being configured.

Table 8-18 Get Feature Configuration Command

Byte

Data field

Request
Data

1

LSB of Artesyn IANA Enterprise Number. A value of CDh is used.

2

2nd byte of Artesyn IANA Enterprise Number. A value of 65h is used.

3

MSB of Artesyn IANA Enterprise Number. A value of 00h is used.

4

Feature Selector. For more information, see

Table 8-17 on page 152

.

Response
Data

1

Completion Code is Generic, plus the following command-specific
completion codes:
80h = feature selector not supported.

2

LSB of Artesyn IANA Enterprise Number. A value of CDh is used.

3

2nd byte of Artesyn IANA Enterprise Number. A value of 65h is used.

4

MSB of Artesyn IANA Enterprise Number. A value of 00h is used.

5

Feature Configuration
00h = disabled (Feature Selector = E0)
01h = enabled (Feature Selector = E0)
02h = restore factory default (golden) (Feature Selector = E1)
C0h = reload selected FPGA image (Feature Selector = E1)
C1h = enabled and activated (Feature Selector = E0)
03h - FFh = reserved

6

Persistency / Duration