4 get feature configuration, Table 8-18, Get feature configuration command – Artesyn ATCA-9405 Installation and Use (May 2014) User Manual
Page 153: Intelligent peripheral management controller

Intelligent Peripheral Management Controller
ATCA-9405 Installation and Use (6806800M71G)
153
8.21.4 Get Feature Configuration
This command is used to retrieve the IPMI feature set being configured.
Table 8-18 Get Feature Configuration Command
Byte
Data field
Request
Data
1
LSB of Artesyn IANA Enterprise Number. A value of CDh is used.
2
2nd byte of Artesyn IANA Enterprise Number. A value of 65h is used.
3
MSB of Artesyn IANA Enterprise Number. A value of 00h is used.
4
Feature Selector. For more information, see
Response
Data
1
Completion Code is Generic, plus the following command-specific
completion codes:
80h = feature selector not supported.
2
LSB of Artesyn IANA Enterprise Number. A value of CDh is used.
3
2nd byte of Artesyn IANA Enterprise Number. A value of 65h is used.
4
MSB of Artesyn IANA Enterprise Number. A value of 00h is used.
5
Feature Configuration
00h = disabled (Feature Selector = E0)
01h = enabled (Feature Selector = E0)
02h = restore factory default (golden) (Feature Selector = E1)
C0h = reload selected FPGA image (Feature Selector = E1)
C1h = enabled and activated (Feature Selector = E0)
03h - FFh = reserved
6
Persistency / Duration