4 manual rollback, 5 retrieving versioning information – Artesyn ATCA-9405 Installation and Use (May 2014) User Manual
Page 119

Intelligent Peripheral Management Controller
ATCA-9405 Installation and Use (6806800M71G)
119
8.4.4
Manual Rollback
To be able to switch from an active component to its rollback version, the HPM1 command
Initiate Manual Rollback
is enhanced with a 2 request data argument, to enable users
to select the component which should be rolledback. This is done to overcome a limitation in
the HPM1 specification. Using this command extension, you can initiate the component
rollback without previous firmware upgrades.
8.4.5
Retrieving Versioning Information
Retrieving the actual and backup version of the components is possible without switching
payload firmware boot banks. We recommend to use fcu for embedded firmware upgrade.
For example, the following terminal output illustrates the component versions:
hayabusa(avh012):119 ./fcu -q -t8a --lan=192.168.42.50
********************[[[[[REPORT BEGIN]]]]]********************
OPERATION : Query
RESULT : SUCCESS
MESSAGE : Device : 0065CD-2003-hpm.1-ipmc
Part number : 123456789123456789123
Part revision :
BANK : A - Operational
Firmware Name : IPMI F/W
Firmware Version : 2.0.00000002
BANK : B - Rollback
Firmware Name : IPMI F/W
Firmware Version : 2.0.00000002
BANK : D - Operational
Firmware Name : IPMI B/L
Firmware Version : 2.0.00000002
BANK : G - Operational
Firmware Name : IPMI F/I
Firmware Version : 0.0.00000000