Intelligent peripheral management controller – Artesyn ATCA-9405 Installation and Use (May 2014) User Manual
Page 143

Intelligent Peripheral Management Controller
ATCA-9405 Installation and Use (6806800M71G)
143
3. This step is not required if the IPMC default is used: default subnet mask 255.255.0.0
To set the subnet mask, execute the following commands:
ipmicmd -k "0
4. This step is not required if the IPMC default is used: default gateway IP address
172.17.0.254
To set the gateway IP address, execute the following commands:
ipmicmd -k "0
5. To enable SOL configuration, the Set_In_Progress flag must be set
ipmicmd -k "0
6. This step is not required if the IPMC default is used: default baud rate is 9600
To set the non-volatile bit-rate, execute the following command:
ipmicmd -k "0
7. To set the SOL_ENABLE flag, execute the following commands:
ipmicmd -k "0
Note: This value is stored internally and sent to the TS when the SOL_ENABLE flag is set with
the IPMI command Set SOL Configuration. This IP address is invalidated by clearing the
SOL_ENABLE
flag.
Note: bit-rate 6 = 9600baud, 7 =19.2kbaud, 8=38.4kbaud
Note: Telnet session is not possible without enabling the SOL.