beautypg.com

Table 2-6, Settings for switch sw4 (for debugging only), Setup – Artesyn ATCA-9405 Installation and Use (May 2014) User Manual

Page 37

background image

Setup

ATCA-9405 Installation and Use (6806800M71G)

37

Table 2-6 Settings for Switch SW4 (for debugging only)

Switch

Description

Default

SW4-1

Manual Power Enable for Packet Processor 1
OFF = SP controlled PP1 power enable
ON = Manual PP1 power enable

OFF

Software controlled (SP) power
enable for PP1

SW4-2

Manual Power Enable for Packet Processor 2
OFF = SP controlled PP2 power enable
ON = Manual PP2 power enable

OFF

Software controlled (SP) power
enable for PP2

SW4-3
(dual
function)

IPMC Watchdog Enable (SW3-3 = OFF)
OFF = Watchdog enabled
ON = Watchdog disabled

OFF

IPMC Watchdog Enabled

Reserved (SW3-3 = ON)

OFF

Do not change

SW4-4

IPMC Console Output Selection
OFF = IPMC console output via debug
connector
ON = IPMC console output via front panel
connector

OFF

IPMC Console Output via
debugging header