2 get serial output command, Table 8-15, Get serial output command – Artesyn ATCA-9405 Installation and Use (May 2014) User Manual

Page 150: Intelligent peripheral management controller

background image

Intelligent Peripheral Management Controller

ATCA-9405 Installation and Use (6806800M71G)

150

IPMI command examples:

To set the serial COM #0 of SP to the front connector instance 0 (default):
ipmicmd -k "0 0 2e 15 cd 65 0 0 0 4" smi 0

To set the IPMC serial to front connector instance 0:
ipmicmd -k "0 0 2e 15 cd 65 0 0 0 2" smi 0

To set the serial COM #0 of PP #0 to the front connector instance 1 (default):
ipmicmd -k "0 0 2e 15 cd 65 0 0 1 0" smi 0

To set the serial COM #0 of PP #1 to the front connector instance 2 (default):
ipmicmd -k "0 0 2e 15 cd 65 0 0 2 1" smi 0

To set the serial COM #0 of SP to the RTM connector instance 0:
ipmicmd -k "0 0 2e 15 cd 65 0 1 0 2" smi 0

To set the serial COM #0 of SP to the terminal server # 0:
ipmicmd -k "0 0 2e 15 cd 65 0 3 0 4" smi 0

To set the serial COM #0 of SP to the terminal server #1:
ipmicmd -k "0 0 2e 15 cd 65 0 3 1 4" smi 0

To set the serial COM #0 of PP #0 to the terminal server #0:
ipmicmd -k "0 0 2e 15 cd 65 0 3 0 0" smi 0

To set the serial COM #0 of PP #1 to the terminal server #1:
ipmicmd -k "0 0 2e 15 cd 65 0 3 1 1" smi 0

8.21.2 Get Serial Output Command

This command allows you to determine which serial output source goes to a particular serial
port connector.

Table 8-15 Get Serial Output Command

Byte

Data field

Request
Data

1

LSB of Artesyn IANA Enterprise Number. A value of CDh is used.

2

2nd byte of Artesyn IANA Enterprise Number. A value of 65h is used.

3

MSB of Artesyn IANA Enterprise Number. A value of 00h is used.