2 environmental considerations, Table 2-22, Environmental requirements – Artesyn ATCA-9405 Installation and Use (May 2014) User Manual
Page 53: Setup

Setup
ATCA-9405 Installation and Use (6806800M71G)
53
2.4.2
Environmental Considerations
As with any printed circuit board, make sure that the air flow to the board is adequate. Chassis
constraints and other factors greatly affect the air flow rate. The environmental requirements
are as follows:
Table 2-22 Environmental Requirements
Requirement
Operating
Non-Operating
Temperature
+5 ºC (+41 °F) to +40 ºC (+104 °F)
(normal operation) according to NEBS
Standard GR-63-CORE
-5 ºC (+23 °F) to +55 ºC (+131 °F)
(exceptional operation) according to
NEBS Standard GR-63-CORE
-40 ºC (-40 °F) to +70 ºC (+158 °F)
(may be further limited by installed
accessories)
Airflow
The blade is designed to operate in a
chassis that provides 35 CFM across the
blade for the stated temperature range
-
Temperature
change
+/- 0.5 ºC/min according to NEBS
Standard GR-63-CORE
+/- 0.5 ºC/min
Relative humidity
5% to 90% non-condensing according to
Artesyn Embedded Technologies-
internal environmental
requirements
5% to 95% non-condensing
according to Artesyn Embedded
Technologies-internal
environmental requirements
Vibration
1 g from 5 to 100 Hz and back to 5 Hz at
a rate of 0.1 octave/minute
5-20 Hz at 0.1 g2/Hz
20-200 Hz at -3.0 dB/octave
Random 20-200 Hz at -3 m/Sec2
Shock
Half-sine, 11 m/Sec, 30 mSec/sec2
Blade level packaging
Half-sine, 6 mSec at 180 m/Sec2
Free fall
1,200 mm/all edges and corners
1.0 m (packaged)
100 mm (unpacked)