beautypg.com

2 environmental considerations, Table 2-22, Environmental requirements – Artesyn ATCA-9405 Installation and Use (May 2014) User Manual

Page 53: Setup

background image

Setup

ATCA-9405 Installation and Use (6806800M71G)

53

2.4.2

Environmental Considerations

As with any printed circuit board, make sure that the air flow to the board is adequate. Chassis
constraints and other factors greatly affect the air flow rate. The environmental requirements
are as follows:

Table 2-22 Environmental Requirements

Requirement

Operating

Non-Operating

Temperature

+5 ºC (+41 °F) to +40 ºC (+104 °F)
(normal operation) according to NEBS
Standard GR-63-CORE
-5 ºC (+23 °F) to +55 ºC (+131 °F)
(exceptional operation) according to
NEBS Standard GR-63-CORE

-40 ºC (-40 °F) to +70 ºC (+158 °F)
(may be further limited by installed
accessories)

Airflow

The blade is designed to operate in a
chassis that provides 35 CFM across the
blade for the stated temperature range

-

Temperature
change

+/- 0.5 ºC/min according to NEBS
Standard GR-63-CORE

+/- 0.5 ºC/min

Relative humidity

5% to 90% non-condensing according to
Artesyn Embedded Technologies-
internal environmental
requirements

5% to 95% non-condensing
according to Artesyn Embedded
Technologies-internal
environmental requirements

Vibration

1 g from 5 to 100 Hz and back to 5 Hz at
a rate of 0.1 octave/minute

5-20 Hz at 0.1 g2/Hz
20-200 Hz at -3.0 dB/octave
Random 20-200 Hz at -3 m/Sec2

Shock

Half-sine, 11 m/Sec, 30 mSec/sec2

Blade level packaging
Half-sine, 6 mSec at 180 m/Sec2

Free fall

1,200 mm/all edges and corners
1.0 m (packaged)
100 mm (unpacked)