3 set feature configuration, Table 8-16, Set feature configuration command – Artesyn ATCA-9405 Installation and Use (May 2014) User Manual
Page 151: Set feature configuration, Intelligent peripheral management controller

Intelligent Peripheral Management Controller
ATCA-9405 Installation and Use (6806800M71G)
151
8.21.3 Set Feature Configuration
This command is used to enable/disable features within the IPMC during runtime.
4
Serial connector type:
0 = Front panel connector
1 = RTM panel connector
2 = reserved
3 = On-board device (that is, Terminal Server, P4080 COM #1 to Intel
COM #0)
All other values are reserved.
5
Serial connector instance number. A sequential number starts from
zero.
Response
Data
1
Completion Code
2
LSB of Artesyn IANA Enterprise Number. A value of CDh is used.
3
2nd byte of Artesyn IANA Enterprise Number. A value of 65h is used.
4
MSB of Artesyn IANA Enterprise Number. A value of 00h is used.
5
Serial output selector. For more information, see
.
Table 8-15 Get Serial Output Command (continued)
Byte
Data field
Table 8-16 Set Feature Configuration Command
Byte
Data field
Request
Data
1
LSB of Artesyn IANA Enterprise Number. A value of CDh is used.
2
2nd byte of Artesyn IANA Enterprise Number. A value of 65h is used.
3
MSB of Artesyn IANA Enterprise Number. A value of 00h is used.
4
Feature Selector. For more information, see