For correctable memory error logging, there are two additional parameters to prevent the
flooding of the event logs. The parameters are:

Error Threshold - Correctable memory errors are logged when the threshold is reached.
The first correctable memory error is always logged.

Error Logging Limit - The number of logged correctable memory errors for a DIMM is
limited. If the last entry in the log is SMBIOS: 'Correctable memory log disabled' and IPMI:
Memory event 'Correctable ECC logging limit reached'. No further correctable errors are
logged for this DIMM.

4.12.2 Error Simulation

For test purposes, it is possible to inject errors.
Enable 'Inject Errors' in 'Event Logs' -> 'SMBIOS Event Log Settings' in BIOS setup.

The following errors are injected short before the OS is booted:

No Console found

IPMI Boot Parameter Checksum error

CPU Self test failure

Bad battery

Table 4-28 Logged Error Events

Error

SMIBIOS

IPMI

Correctable:
- Correctable ECC Memory Error

Single-bit ECC memory error

Sensor: Memory, Offset 00h

Correctable:
- Memory Error Limit Reached
- Correctable ECC logging limit reached

Correctable memory log disabled

Sensor: Memory, Offset 05h

Uncorrectable:
- Uncorrectable ECC Memory Error

Multi-bit ECC memory error

Sensor: Memory, Offset 01h

PCI PERR

PCI Parity Error

Sensor: Critical Interrupt,
Offset 04h PCI PERR

PCI SERR

PCI System Error

Sensor: Critical Interrupt,
Offset 05h PCI SERR