Delta Electronics AC Motor Drive VFD-EL User Manual
Page 84

Chapter 4 Parameters|
Revision August 2008, 2ELE, V1.02
4-41
40%
50%
60%
For 460V Series
80%
90%
100%
70%
Carrier
Frequency
R
a
te
d
C
u
rr
e
n
t
(%
)
2kHz
4kHz
8kHz
10kHz
12kHz
6kHz
50 with mounting method A
℃
40 with mounting method B
℃
25 with mounting method B
℃
40%
50%
60%
For 115V/230V Series
80%
90%
100%
2kHz
4kHz
8kHz
10kHz
12kHz
6kHz
70%
R
a
te
d
C
u
rr
e
n
t
(%
)
Carrier
Frequency
50 with mounting method A
℃
40 with mounting method B
℃
35 with mounting method A
℃
25 with mounting method B
℃
02.04
Motor Direction Control
Factory Setting: 0
Settings
0
Forward/Reverse operation enabled
1
Reverse
operation
disabled
2
Forward
operation
disabled
This parameter is used to disable one direction of rotation of the AC motor drive direction of
rotation.
02.05
Line Start Lockout
Factory Setting: 1
Settings
0
Disable. Operation status is not changed even if operation
command source Pr.02.01 is changed.
1
Enable. Operation status is not changed even if operation command
source Pr.02.01 is changed.
2
Disable. Operation status will change if operation command source
Pr.02.01 is changed.
3
Enable. Operation status will change if operation command source
Pr.02.01 is changed.
This parameter determines the response of the drive upon power on and operation command
source is changed.
Pr.02.05
Start lockout (Run when power is ON)
Operation status when operation
command source is changed
0
Disable (AC motor drive will run)
Keep previous status
1
Enable (AC motor drive doesn’t run)
Keep previous status
2
Disable (AC motor drive will run)
Change according to the new
operation command source
3
Enable (AC motor drive doesn’t run)
Change according to the new
operation command source