Chapter 4 Parameters|
Revision August 2008, 2ELE, V1.02
4-19
Parameter
Explanation
Settings
Factory
Setting
Customer
10.04
Derivative Control
(D)
0.00 to 1.00 sec
0.00
10.05
Upper Bound for
Integral Control
0 to 100%
100
10.06
Primary Delay Filter
Time
0.0 to 2.5 sec
0.0
10.07
PID Output Freq
Limit
0 to 110%
100
10.08
PID Feedback
Signal Detection
Time
0.0 to 3600 sec (0.0 disable)
60.0
0: Warn and RAMP to stop
1: Warn and COAST to stop
10.09
Treatment of the
Erroneous PID
Feedback Signals
2: Warn and keep operation
0
10.10
Gain Over the PID
Detection Value
0.0 to 10.0
1.0
10.11
Source of PID Set
point
0.00 to 600.0Hz
0.00
10.12
PID Feedback Level 1.0 to 50.0%
10.0
10.13
Detection Time of
PID Feedback
0.1 to 300.0 sec
5.0
10.14
Sleep/Wake Up
Detection Time
0.0 to 6550 sec
0.0
10.15
Sleep Frequency
0.00 to 600.0 Hz
0.00
10.16
Wakeup Frequency
0.00 to 600.0 Hz
0.00
0: By PID control
10.17
Minimum PID
Output Frequency
Selection
1: By minimum output frequency (Pr.01.05)
0
10.18
PID Control
Detection Signal
Reference
1.0 to 99.9
99.9
10.19
PID Calculation
Mode Selection
0: Series mode
1: Parallel mode
0