Chapter 4 Parameters|

Revision August 2008, 2ELE, V1.02

4-7

Parameter Explanation

Settings

Factory

Setting

Customer

0: by Current Freq Command

1: by Zero Freq Command

02.14

Initial Frequency
Selection (for
keypad & RS485)

2: by Frequency Display at Stop

0

02.15

Initial Frequency
Setpoint (for keypad
& RS485)

0.00 ~ 600.0Hz

60.00

02.16

Display the Master
Freq Command
Source

Read Only
Bit0=1: by First Freq Source (Pr.02.00)
Bit1=1: by Second Freq Source (Pr.02.09)
Bit2=1: by Multi-input function

##

02.17

Display the
Operation
Command Source

Read Only
Bit0=1: by Digital Keypad
Bit1=1: by RS485 communication
Bit2=1: by External Terminal 2/3 wire mode
Bit3=1: by Multi-input function

##

02.18

User-defined Value
2 Setting

0 to Pr.00.13

0

02.19

User-defined Value
2

0 to 9999

##

Group 3 Output Function Parameters

Parameter Explanation

Settings

Factory

Setting

Customer

0: No function

1: AC drive operational

2: Master frequency attained

3: Zero speed

4: Over torque detection

5: Base-Block (B.B.) indication

6: Low-voltage indication

7: Operation mode indication

8: Fault indication

9: Desired frequency attained

03.00 Multi-function

Output Relay (RA1,
RB1, RC1)

10: Terminal count value attained

8