beautypg.com

Delta Electronics AC Motor Drive VFD-EL User Manual

Page 43

background image

Chapter 3 Keypad and Start Up|

3-6

Revision August 2008, 2ELE, V1.02

1.

After applying the power, verify that LED

display shows F 60.0Hz.

2. Press

key to set frequency to around

5Hz.

3. Press

key for forward running. And if

you want to change to reverse running, you
should press

. And if you want to

decelerate to stop, please press

key.

4.

Check following items:

„

Check if the motor direction of rotation

is correct.

„

Check if the motor runs steadily

without abnormal noise and vibration.

„

Check if acceleration and deceleration

are smooth.

RUN

If the results of trial run are normal, please start the formal run.

NOTE

1.

Stop running immediately if any fault occurs and refer to the troubleshooting guide for

solving the problem.

2.

Do NOT touch output terminals U/T1, V/T2, W/T3 when power is still applied to R/L1,

S/L2, T/L3 even when the AC motor drive has stopped. The DC-link capacitors may still

be charged to hazardous voltage levels, even if the power has been turned off.

3.

To avoid damage to components, do not touch them or the circuit boards with metal

objects or your bare hands.