beautypg.com

Weld by energy – Dukane DPC II Plus 9001:2000 User Manual

Page 89

background image

79

Dukane Manual Part No. 403–566–01

Section 7 – Process Control Menu

Using the four arrow keys, enter the weld time. Press
the

ENTER

key when you have completed the data

entry. This displays the Weld Method selection
screen for Pressure Two as shown in Figure 7–41.

This time select

WELD BY ENERGY

and press the

ENTER

key. This brings up the data entry screen

for pressure two as shown below in Figure 7–42.
If you do not have a Power Output module, the
energy option will not appear. Figure 7–44 shows
the logical flow for dual pressure mode without
the energy option.

Again use the arrow keys to enter the weld en-
ergy. This parameter is labeled E

2

weld

on the flow

chart. Press the

ENTER

key when you have fin-

ished to bring up the data entry screen for P2
Maximum Weld Time as shown in Figure 7–43.
This value sets the time limit to reach the P2 weld
energy. This time limit applies only to the P2 cycle.

WELD METHOD P2
WELD BY TIME
WELD BY ENERGY

WELD ENERGY P2

75 J

MAX WELD TIME P2

0.350 SEC

PROCESS CONTROL
WELD MODE
HOLD TIME
AFTERBURST

If we select energy for the P1 cycle, it will have
its own maximum weld time limit. Press the

ENTER

key to return to the Process Control

menu as shown in Figure 7–45.

WELD MODE
SINGLE PRESSURE
DUAL PRESSURE

WELD TIME P1

0.500 SEC

WELD TIME P2

0.250 SEC

Dual Pressure Weld Mode Menus
w/o Power Output Module

Figure 7–41

Pressure Two Weld Method Selection Menu

Figure 7–42

Pressure Two Weld Energy Data Entry

Figure 7–43

Pressure Two Max Weld Time Data Entry

Figure 7–44

Dual Pressure Time Only Menus

Figure 7–45