beautypg.com

Manual, Auto stop, Head up on auto stop – Dukane DPC II Plus 9001:2000 User Manual

Page 88: Trigger type, Momentary, Weld mode, Dual pressure, Weld by time

background image

78

Dukane Manual Part No. 403–566–01

DPC

II Plus and EZ Welder System – User’s Manual

The menu changes to display the Initiate mode as
shown in Figure 7–35. We will assume a standard
press configuration using the dual palm operate
switches. Since we will manually trigger the press,
move the cursor to

MANUAL

and press

ENTER

.

You can see from the flow chart in Figure 7–30
that we bypass both the

AUTO STOP

and

HEAD UP

ON AUTO STOP

menus when we select manual

mode. The next menu displayed is

TRIGGER TYPE

which is shown in Figure 7–36.

The trigger type used for most welding conditions
should be

MOMENTARY

. Use the down arrow key

to select Momentary and press

ENTER

. We are now

at the central Process Control menu. It is shown
below in Figure 7–37.

The cursor is pointing to Weld Mode by default.
Note there is a small difference between the word-
ing of the Process Control menu for Press and for

INITIATE MODE
MANUAL
AUTO

TRIGGER TYPE
MAINTAINED
MOMENTARY

PROCESS CONTROL
WELD MODE
HOLD TIME
AFTERBURST

Auto Probe. The Press option reads Weld Mode
whereas the Auto Probe menu reads Weld Method.
We leave

WELD MODE

selected and press

ENTER

.

The next menu (Figure 7–38) appears only in press
mode. It is titled Weld Mode and offers a choice of
welding modes. You must have a dual–pressure
press to use the dual pressure mode. A single pres-
sure press displays Weld Method (see Figure 7–15).

To demonstrate the complete set of options, we
will select

DUAL PRESSURE

and push the

ENTER

key. We can select time or energy as the welding
parameter during the P1 portion of the welding
cycle. This corresponds to the block labeled

PRES-

SURE 1

in Figure 7–58. Select

WELD BY TIME

and

press the

ENTER

key.

A data entry screen appears requesting the value
of the weld time for pressure one. On the flow
chart (Figure 7–30) this is labeled T

1

weld

. The data

entry screen is shown below in Figure 7–40.

WELD MODE
SINGLE PRESSURE
DUAL PRESSURE

WELD METHOD P1
WELD BY TIME
WELD BY ENERGY

WELD TIME P1

0.500 SEC

Figure 7–35

Press Initiate Mode Menu

Figure 7–36

Press Trigger Type

Figure 7–37

First Pass Through Process Control Menu

Figure 7–38

Single or Dual Pressure Selection Menu

Figure 7–39

Pressure One Weld Method Selection Menu

Figure 7–40

Pressure One Weld Time Data Entry