Manual, Auto stop, Head up on auto stop – Dukane DPC II Plus 9001:2000 User Manual
Page 88: Trigger type, Momentary, Weld mode, Dual pressure, Weld by time
78
Dukane Manual Part No. 403–566–01
DPC
™
II Plus and EZ Welder System – User’s Manual
The menu changes to display the Initiate mode as
shown in Figure 7–35. We will assume a standard
press configuration using the dual palm operate
switches. Since we will manually trigger the press,
move the cursor to
MANUAL
and press
ENTER
.
You can see from the flow chart in Figure 7–30
that we bypass both the
AUTO STOP
and
HEAD UP
ON AUTO STOP
menus when we select manual
mode. The next menu displayed is
TRIGGER TYPE
which is shown in Figure 7–36.
The trigger type used for most welding conditions
should be
MOMENTARY
. Use the down arrow key
to select Momentary and press
ENTER
. We are now
at the central Process Control menu. It is shown
below in Figure 7–37.
The cursor is pointing to Weld Mode by default.
Note there is a small difference between the word-
ing of the Process Control menu for Press and for
INITIATE MODE
MANUAL
AUTO
TRIGGER TYPE
MAINTAINED
MOMENTARY
PROCESS CONTROL
WELD MODE
HOLD TIME
AFTERBURST
Auto Probe. The Press option reads Weld Mode
whereas the Auto Probe menu reads Weld Method.
We leave
WELD MODE
selected and press
ENTER
.
The next menu (Figure 7–38) appears only in press
mode. It is titled Weld Mode and offers a choice of
welding modes. You must have a dual–pressure
press to use the dual pressure mode. A single pres-
sure press displays Weld Method (see Figure 7–15).
To demonstrate the complete set of options, we
will select
DUAL PRESSURE
and push the
ENTER
key. We can select time or energy as the welding
parameter during the P1 portion of the welding
cycle. This corresponds to the block labeled
PRES-
SURE 1
in Figure 7–58. Select
WELD BY TIME
and
press the
ENTER
key.
A data entry screen appears requesting the value
of the weld time for pressure one. On the flow
chart (Figure 7–30) this is labeled T
1
weld
. The data
entry screen is shown below in Figure 7–40.
WELD MODE
SINGLE PRESSURE
DUAL PRESSURE
WELD METHOD P1
WELD BY TIME
WELD BY ENERGY
WELD TIME P1
0.500 SEC
Figure 7–35
Press Initiate Mode Menu
Figure 7–36
Press Trigger Type
Figure 7–37
First Pass Through Process Control Menu
Figure 7–38
Single or Dual Pressure Selection Menu
Figure 7–39
Pressure One Weld Method Selection Menu
Figure 7–40
Pressure One Weld Time Data Entry