beautypg.com

System power output display – Dukane DPC II Plus 9001:2000 User Manual

Page 42

background image

32

Dukane Manual Part No. 403–566–01

DPC

II Plus and EZ Welder System – User’s Manual

System Power Output Display

The tricolor System Power Output Display indi-
cates the percentage of ultrasonic power being
drawn by the load.

Green

Eight green vertical bars indicating
10% to 80% power output are dis-
played during normal operation. Fig-
ure 4-5 shows the display indicating
80% output power.

Yellow

Two yellow bars for 90% and 100%
power output warn that the genera-
tor is operating near its maximum
rated output.

Red

The last red bar indicates that the
generator is in an overload condition
delivering more than its rated out-
put power. Figure 4-6 shows the red
overload and two yellow warning in-
dicators. The red warning indicator
lights up just prior to an overload
condition. The ultrasonic signal is
shut down when an overload condi-
tion occurs.

GREEN

YELLOW

RED

Figure 4–6 Warning Indicators

Figure 4–5 Normal Operation

NOTE

The available output power is directly propor-
tional to the Amplitude setting.
Example: A 2200 Watt rated DPC set to 80%
Amplitude will overload at 1760 Watts.
(2200W

x

0.80 = 1760 Watts)