Press control module – Dukane DPC II Plus 9001:2000 User Manual
Page 58
48
Dukane Manual Part No. 403–566–01
DPC
™
II Plus and EZ Welder System – User’s Manual
Press Control Module
Part No. 110–3938
This optional module enables the DPC II Plus to
control a Dukane Model 210, 220 or 410 press or
custom automation. This module is also installed
on a EZ Welder™ System. The module is
illustrated in Figure 5–8. The cabling hookup to a
Dukane press system is shown in Figure 3–8.
Pin No.
Type
Function
Signal Description
1
Input
Activation Switch 1
Normally Open (N.O.) dry contact closure to ground
2
Input
Activation Switch 2
Normally Open (N.O.) dry contact closure to ground
3
Input
Hardware Abort Power In
Normally Closed (N.C.) emergency switch contact
4
Input
Software Abort
Normally Open (N.O.) dry contact closure to ground
5
Ground
Internal Ground
Internal Ground (Gnd)
6
Ground
Internal Ground
Internal Ground (Gnd)
7
Ground
Internal Ground
Internal Ground (Gnd)
8
Input
Automation Input
Normally Open (N.O.) dry contact closure to ground
9
+22V DC
Hardware Abort Power Out
Normally Closed (N.C.) emergency switch contact
J901
Thruster Cable
Connection
J902 Press
Base Cable
Connector
Press Control
Module
P/N 110–3938
1
1
5
9
6
18
36
19
Molex
DB–9
36–Contact
Subminature D
Figure 5–8
Press Control Module
Table 5—
V
J902 Press Base Connector Pinout
Figure 5–9
Press
Connector Pin
Identification