Trigger method, Untimed hand probe, Timed hand probe – Dukane DPC II Plus 9001:2000 User Manual
Page 76: Press the, And you are ready to weld, Mode, Enter
66
Dukane Manual Part No. 403–566–01
DPC
™
II Plus and EZ Welder System – User’s Manual
Press the
MODE
key to display the Process Setup
menu. In Process Setup, the cursor should be point-
ing to Process Control as shown in Figure 7–5. If
it is not, press the up–arrow and down–arrow key
to navigate the triangle pointer to select Process
Control. Press the
ENTER
key to activate the se-
lected menu.
Since the DPC II Plus reconfigures the user inter-
face to be consistent with the installed modules,
only the portion of the menu structure relating to
hand probe operation is displayed. The only op-
tion for the Process Control screen is the Trigger
Method which is shown in Figure 7–6.
The flow chart for the Process Control menu with
a hand probe connected is shown in Figure 7–7. If
you do not have a Power Output module installed,
the Energy Weld Method will not be displayed.
Untimed Hand Probe
Untimed Hand Probe operation has no parameters
to enter. The generator is triggered whenever the
hand probe trigger is engaged and continues until
the trigger is released. Press
ENTER
and you are
ready to weld (
RTW
).
Timed Hand Probe
In Timed Hand Probe mode, the welding stops when-
ever the trigger is released or the specified weld time
PROCESS SETUP
PROCESS CONTROL
PROCESS LIMITS
UTILITIES
TRIGGER METHOD
TIMED HAND PROBE
UNTIMED HAND PROBE
TRIGGER METHOD
TIMED HAND PROBE
TIMED
HAND
PROBE
UNTIMED
HAND
PROBE
RTW
RTW
WELD METHOD
TIME
ENERGY
UNTIMED HAND PROBE
ENTER
ENTER
ENTER
ENTER
ENTER
T
w
eld
E
w
eld
T
max
Hand
Probe
Trigger
Switch
Hand
Probe
Trigger
Switch
Figure 7–11
Figure 7–10
Figure 7–8
Figure 7–9
Figure 7–6
Maximum
E
weld
Minimum
E
weld
= 12,000 Joules
= 1 Joule*
Maximum
T
max
Minimum
T
max
= 30.000 Seconds
= 0.001 Second*
Maximum
T
weld
Minimum
T
weld
= 29.999 Seconds
= 0.001 Second*
* These values can be set to zero, but will not
produce any output. The values listed represent
the resolution and are the smallest values that
will produce any output signal.
T
we
ld
RTW = Ready To Weld
LEGEND
= Front Panel ENTER Key
(Section 4.3 – Menu Keys)
ENTER
= Parameter Value Entry
T = Time
E = Energy
Figure 7–7
Hand Probe Flow Chart
Figure 7–5
Process Setup Menu
Figure 7–6
Process Control Trigger Method Menu