22

Dukane Manual Part No. 403–566–01

DPC

II Plus and EZ Welder System – User’s Manual

ƽ

DUKANE CORP
ST. CHARLES, IL 60174
MADE IN USA

S E R I A L N U M B E R

U S 1 0 0 0 0

– WARNING! –

POWERLINE MUST BE GROUNDED

AT OUTLET

REMOVE ALL POWER BEFORE

REMOVING COVER OR CONNECTING

OR DISCONNECTING CABLES.

ULTRASOUND

OUTPUT

SYSTEM OUT

SYSTEM IN

J1

U. S . PAT E N T 4 , 2 7 7 , 7 1 0

– WARNING–

POWER LINE MUST BE

GROUNDED AT OUTLET

LINE VOLTAGE

200–240Vac 50/60Hz

15A

M O D E L N U M B E R

2 0 0 - 2 4 0 VAC, 5 0 - 6 0 H z , 1 5 A

Remote Ampltd

Control Mod.

Current Loop
Status

POS

NEG

SHLD

+

Power Monitor

Jacks

Power Signal

Output Module

Power
Signal
Output

Zero

Adjust

1

2

3

4

5

6

7

8

Earth Ground

#14 Gauge
Wire

110 VAC or
220 VAC

Grounding Lug

Grounding
Lug

Ultrasound

Input(s)

Automation
Control

Multi–Probe

Master Module

Ultrasonic Input

RG62B/U Coax

Status Output
P/N 200–1302

Coaxial Cable(s)

RG62B/U

#14 Gauge Wire

Automation

Equipment

P/N 200–1203

P/N 200–479

Figure 3-6 DPC II Plus Multiple Probe Conntroller Cable Connections

NOTE

The automated system cabling schematics in Fig-
ures 3–5, 3–6 and 3–7 are intended to represent
connections for a typical automation system. Your
system cabling may vary slightly from the diagrams.

CAUTION

To ensure safe and trouble–
free operation, ground the
DPC chassis and probe
mount as shown in Figures
3–4 to 3–7.
Use a STAR configuration
(illustrated below). Do not
DAISY CHAIN the grounds.

Multiple Probe System

Step 1.

Ground the DPC II Plus chassis and
the probe support.

Step 2.

First attach a short coaxial cable from

the rear-panel DPC generator U/S
output J1 (see Figure 3–6) to the MPC
U/S input.

Step 3.

Attach another high voltage coax cable

from the rear MPC channel 1 probe
output to the first probe. Attach a
separate cable from each output
channel to each probe.

Step 4.

Connect the automation control cable
from the user–supplied automation
equipment to the System Input rear
panel HD-15 connector.

Step 5.

Attach the status output cable from the

user–supplied automation equipment to
the System Output DB-25 connector.

Step 6.

Attach the power cord to the DPC II
Plus and plug the other end into an
approved AC outlet.

Earth

Ground

#14 Gauge

Stranded or

Solid Wire

#14 Gauge

Stranded or

Solid Wire

Thruster or

Probe Mount

Grounding Lug

DPC Chassis

Grounding

Lug