Generator

The generator will not produce an output signal
when triggered if it is OFF LINE. Make sure that
the green power indicator [A] is lit. The status dis-
play should indicate ON LINE which is marked
as [B] in Figure 12–2. If the generator is OFF
LINE, press the ON LINE control key [C].

Operate Input

If you are using a hand probe, make sure the con-
trol cable is connected to the System Input con-
nector. The trigger on the hand probe activates the
Ultrasonic output through the control cable.

If you have supplied custom automation signals,
pin 8, or pins 3 & 4 of the Operate Input must be
used to trigger the Ultrasonic output. The system
control inputs are user configurable. Refer to Sec-
tion 5, Jumper Block SH707 for a detailed descrip-
tion of the options. The factory default setting
(JU724) is a contact closure to ground. If you are
using the isolated source jumper position (JU 726),
then the input requires a minimum of 5V to trig-
ger the generator.

STATUS

FAULT

ON LINE

INPUT TEST

OVERTEMP

OVERLOAD

OFF LINE

ON

LINE

TEST

OFF

LINE

0

20

40

60

80 100

PERCENTAGE OF AVAILABLE POWER

PERCENTAGE OF AVAILABLE POWER

SYSTEM POWER OUTPUT

Ạạ Ả

Figure 12–2

Generator ON LINE Key and Indicator

NOTE

Figure 5–3 shows the male cable end of the
System Input connector and is repeated here.
The cable end connector is a mirror image of
the female panel connector shown in Figure
5–2. Make sure you have correctly wired the
connector if you are using custom automa-
tion signals.

1 2 3 4 5

6

10

11 12 13 14 15