Startup and self–test, Ạấ ạ ả ả – Dukane DPC II Plus 9001:2000 User Manual
Page 129
119
Dukane Manual Part No. 403–566–01
Section 11 – DPC Checkout
Startup and Self–Test
1. Push the rear panel AC breaker switch to the
ON
position (see Figure 3–3 or 3–9 for the
switch location.)
2. Push the front panel AC power switch to the
ON position (marked I on the switch.) This is
labled A in Figure 11–1.
3. The
INPUT TEST
indicator in the Status Dis-
play (B) flashes red for 5 to 10 seconds. This
indicates the power-up self test is running.
When the test has successfully completed, the
INPUT TEST
indicator goes dark.
4. The green power indicator (C in Figure 11–1)
should then light up. The yellow
OFF LINE
sta-
tus indicator (D in Figure 11–1) should also
be lit. After subsequent power cycles, the DPC
will return to its last state (
ON LINE
or
OFF
LINE
) when the front panel AC power switch
is turned
ON
again.
5. Press the
ON LINE
generator control key on
the front panel (labeled E in Figure 11–1.) The
green
ON LINE
indicator in the Status Display
(labeled F in Figure 11–2) should now be lit.
NOTE
If the INPUT TEST indicator does not flash,
check the AC line input. Both the rear panel
and front panel AC breaker switches must be
in the ON position, and the DPC line cord must
be properly connected to a live AC outlet.
If the INPUT TEST indicator flashes and then
remains in a steady red state –
1. The AC line level may be out of speci-
fied operating range.
2. The DPC may have an inter nal
fault preventing normal opertion.
NOTE
If either of the AC Breakers open, they will flip
the switch to its Off position marked by the O.
STATUS
FAULT
ON LINE
INPUT TEST
OVERTEMP
OVERLOAD
OFF LINE
ON
LINE
TEST
OFF
LINE
0
20
40
60
80 100
PERCENTAGE OF AVAILABLE POWER
PERCENTAGE OF AVAILABLE POWER
SYSTEM POWER OUTPUT
Ạ
Ấ
ạ
Ả
ả
NOTE
If a Press Control module is installed, and
the ON LINE and OFF LINE indicators do not
light, check the follwoing items.
1. A Press Base cable (P/N 200–1124) must
be connected to J35 on the press and
J902 on the DPC (Cable 3 in Figure 3–8).
2. The Emergency Stop switch must be in
its reset position (pulled out).
3. In place of a press cable, a jumper block
(Dukane P/N 200–1293) can be
installed on J902 (see Figure 3–4).
Figure 11–1
Front Panel Startup Controls and Indicators