beautypg.com

Limit definition menu, Limit definition, Process limits process setup – Dukane DPC II Plus 9001:2000 User Manual

Page 70: Suspect bad, Limits

background image

60

Dukane Manual Part No. 403–566–01

DPC

II Plus and EZ Welder System – User’s Manual

Limit Definition Menu

The Limit Definition menu has two classes of
settings. The first class is the suspect limits and
the second class is for bad part limits. When
applicable, choices for time, energy, total time
and total energy are available. A simplified flow
chart for the Limit Definition menu is shown in
Figure 6–7. Although not indicated in this draw-
ing, both upper and lower bounds can be set for
each limit. The Limit Definition menu is cov-
ered in greater detail in Section 8.

Total Limits
Available Only with
Press Controller in
Dual Pressure Mode

LIMIT DEFINITION

SUSPECT
BAD

TIME

ENERGY

TOTAL TIME

TOTAL ENERGY

PROCESS

LIMITS

WELD

TIME P2

WELD

TIME P1

PROCESS

LIMITS

WELD

ENERGY P2

WELD

ENERGY P1

TOTAL

WELD TIME

TOTAL

WELD ENERGY

LIMITS

PROCESS

LIMITS

PROCESS

SETUP

Figure 6–7

Limit Definition Menu Flowchart