beautypg.com

Process control panel, Menu function keys – Dukane DPC II Plus 9001:2000 User Manual

Page 43

background image

33

Dukane Manual Part No. 403–566–01

Section 4 – Controls & Displays

3. Process Control Panel

Menu Function Keys

The menu keys are shown in Figure 4–7. Their
function is described going across each row start-
ing at the upper left.

Pressing the GEN. INFO key displays
the DPC model, the firmware version
and the installed modules. A readout
for a DPC II Plus equipped with both
a Press Control module and a Power
Signal Output Module is shown in
Figure 4–8A. The DPC EZ Series is
shown in Figure 4–8B. Press CAN-
CEL to return to the previous menu.

The up arrow key increments the data
value each time it is pushed. Hold-
ing the key in continuously incre-
ments the value. This key is also used
to move the cursor up one line on a
menu selection screen

Pressing the HOLD key immediately
brings you to the Hold Time data
entry menu. You can quickly check
and/or change the setting using the
four arrow keys. Pressing ENTER
completes the process and returns
you to your last menu screen.

Pressing the WELD P1 key displays
the parameter(s) for the first pressure
setting. The value(s) can be quickly
checked and/or altered without go-
ing back through the menu sequence.
Pressing ENTER completes the pro-
cess and returns you to your last
menu screen.

Pressing the left arrow key selects
the next digit to the left of a param-
eter setting. The key is used when
entering values and moves the flash-
ing bar under the selected digit. The
selection wraps around to the right
digit after the left most digit posi-
tion is reached.

+

HOLD

WELD

P1

WELD

P2

GEN.
INFO

AMP.

ADJUST

CANCEL

ENTER

MODE

Amplitude
Adjust

Decrement

Enter

Right
Arrow

Cancel

Weld
Pressure 2

(DPC II Plus only)

General
Information

Increment

Hold

Weld
Pressure 1

Left

Arrow

Mode

DPC II Plus v1.50
PRESS + ENERGY
MORE INFO:
www.dukcorp.com/us/

GEN.
INFO

WELD

P1

HOLD

EZ Series v1.50
PRESS SYSTEM
MORE INFO:
www.dukcorp.com/us/

Figure 4–7 Menu Keys

Figure 4–8A DPC II Plus GEN INFO Display

Figure 4–8B DPC EZ GEN INFO Display

NOTE

For three of the ‘hot’ keys (HOLD, WELD P1,
and WELD P2), data can only be entered or
modified after the programming setup is